manhole connector nitrile

PSX: Direct Drive Nitrile

PSX: Direct Drive Nitrile is a high-performance flexible pipe-to-manhole connector that offers easy installation and long-term performance in one convenient product.

Category:
Download Literature

Nitrile pipe to manhole connectors offer the added ability to resist common underground contaminants including hydrocarbons and many mixed chemistries.

Whether you core or cast your holes, PSX: Direct Drive Nitrile fits right into your production methods, ready to seal your toughest applications every time.

How It Works

  • The connector fits into a cast or cored hole.
  • A power sleeve made from tempered series 304 stainless steel expands with a certified installation wrench.
  • Take-up clamps made from series 304 stainless steel with quick adjusting screws secure the connector to the pipe.

Why It's Better

  • Nitrile rubber resists most chemicals and hydrocarbons found in effluent and soils.
  • Safely install from outside of the manhole preventing falls from crawling down into structures.
  • All stainless-steel components with no welds or rivets creating a stronger product.
  • Precision molding provides accurate compensation for hole size variations.
  • Contains chemically resistant stainless steel.
  • Contractor can save time and money by backfilling immediately.

Where To Use

  • Manholes
  • Wet wells
  • Square pump and lift stations • Stormwater structures
  • On-site treatment structures • Junction chambers
  • Grease interceptors
  • Vaults

Meets or Exceeds

  • ASTM C 923 – Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes, and Laterals
  • ASTM C 1619 Class D (Material Spec)
  • ASTM C 1244 – Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test
  • ASTM C 1478 – Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes and Laterals
  • ASTM F 2510 – Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures and Corrugated High Density Polyethylene Drainage Pipes
TYPICAL TEST RESULTS for PSX: Direct Drive - Nitrile (as in ASTM C 923, C 1478, and C 443)
TestASTM Test MethodTest RequirementsTypical Result
CHEMICAL RESISTANCE;
1N SULFURIC
ACID and 1N
HYDROCHLORIC ACID
D 534, AT 22ºC FOR
48 HRS
NO WEIGHT LOSS
NO WEIGHT LOSS
NO WEIGHT
LOSS
NO WEIGHT
LOSS
TENSILE STRENGTHD 412 1200 PSI, MIN.1403 PSI
ELONGATION AT
BREAK
D 412 350%, MIN563%
HARDNESSD 2240 (SHORE A
DUROMETER)
±5 FROM THE
MANUFACTURER’S
SPECIFIED HARDNESS
<2
ACCELERATED
OVEN-AGING
D 573, 70± 1ºC
FOR 7 DAYS
DECREASE OF 15%,
MAX. OF ORIGINAL
TENSILE STRENGTH, DECREASE
OF 20%, MAX.
OF ELONGATION
-3% TENSILE
CHANGE, -10%
ELONGATION
CHANGE
COMPRESSION TESTD 395, METHOD B,
AT 70ºC FOR 22 HRS
DECREASE OF 25%,
MAX. OF ORIGINAL DEFLECTION
10%
WATER ABSORPTIOND 471 IMMERSE 0.75
BY 2-IN.SPECIMEN
IN DISTILLED WATER
AT 70ºC FOR 48 hrs
INCREASE OF 10%,
MAX. OR ORIGINAL BY
WEIGHT
2.70%
OZONE RESISTANCED 1171RATING 0PASS
LOW-TEMP,
BRITTLE POINT
D 746NO FRACTURE AT -40ºCPASS
TEAR RESISTANCED624, METHOD B200 LBF/IN (MIN.)255 LBF/IN.
OIL RESISTANCED 471; ASTM IRM 903
AT 100ºC FOR 70HRS
80% MAX VOL. CHANGE-1.9%

Pipe-to-Manhole and Structure Connector Specification for Sanitary and Storm Sewer Applications:

All pipe-to-manhole and structure connections shall meet and or exceed ASTM C 923, Standard Specification for Resilient Connectors Between Reinforced Concrete Manholes, Structures, Pipes and laterals.

All mechanical devices, including castings, bolt assemblies, adjusters shall use non-magnetic 300 series stainless steel with no welds or rivets in its assemblies.

The installation of the connector shall be accomplished at one time and shall require no additional adjustments or installation at a later time to insure a watertight seal.

Take up clamps shall use non-magnetic 304 series stainless steel and be installed in the field using a T-Handle Torque wrench set to 60 inch-pounds and installation shall follow manufacturer’s instructions.

The connector shall be PSX: Direct Drive Nitrile and PSX: Nylo Drive Nitrile as manufactured by PressSeal Corporation of Fort Wayne, IN or approved equal.

HOLE SIZE
RANGE
PSX: DD NITRILE
SIZE and DESCRIPTION
GASKET I.D.PIPE O.D.
ACCOMMODATION
RANGE
TAKE-UP
CLAMP
MINIMUM
SIZE ROUND
STRUCTURE
(INCHES/mm)
MINIMUM
SPAN/RISE
STRAIGHT WALL
(INCHES/mm)
INCHmmINCHmmINCHmmQTYPART #
REQUIRES BLACK SHORT 7/16" TORQUE WRENCH PRESET TO 12 FT/LBS PART # 850.605
8.00 - 8.20203- 208 mm8 QRS STEP “S” NITRILE
8 QRS STEP “R” NITRILE
8 QRS STEP “Q” NITRILE
PSX: DD 8 QRS NITRILE
2.20
3.50
4.60
N/A
56 mm
89 mm
117 mm
N/A
1.70 TO 2.50
2.75 TO 3.75
3.75 TO 4.80
1.70 TO 4.80
43 - 64 mm
70 - 95 mm
95 - 122 mm
43 - 122 mm
1
1
1
1
600-088
600-088
600-088
600-088
36 (900 mm)16 (400 mm))
12.00- 12.20305 - 310 mm12Y PSX: DD NITRILE
12 M PSX: DD NITRILE
6.50
8.63
165 mm
219 mm
5.70 TO 6.90
8.00 TO 9.10
145 - 175 mm
203 - 231 mm
1
1
600-128
600-152
36 (900 mm)20 (500 mm)
14.00 - 14.20356 - 361 mm14 M PSX: DD NITRILE10.35263 mm9.75 TO 11.10248 - 282 mm1600-18836 (900 mm)) 22 (550 mm)
REQUIRES BLUE 1/2" TORQUE WRENCH PRESET TO 20 FT/LBS PART # 850.610
16.00 - 16.20406- 411 mm16 M PSX: DD NITRILE12.75324 mm12.05 TO 13.30306 - 338 mm1600-23236 (900 mm)24 (600 mm)
18.00 - 18,20457 - 462 mm18 M PSX: DD-2 NITRILE15.35390 mm14.60 TO 15.500 371 - 394 mm2600-29636 (900 mm)26 (650 mm)
22.00 - 22.20559 - 564 mm22 M PSX: DD-2 NITRILE18.70475 mm18.00 TO 19.20457 - 488 mm2600-37642 (1067 mm)30 (762 mm)